Terms of Use and Technical Data Print E-mail

Terms of Use and Technical Data

 

 

CG4

CG4-1

CGD4-1

CG6

CG8

CG7

CG9

Rated Insulation Voltage Ue

 

 

 

 

IEC 60947-3, EN 60947-3

 

 

 

 

 

 

VDE 0660 Part 107

V


440

440

440

690

690

SEV max.

V

400

400

-

690

690

UL / Canada

V

300

300

300

300

600

CEE 24

V

380

380

-

380

380

Rated Impulse Withstand Voltage Uimp

 

kV

4

4

upon request

6

6

Rated thermal Current Iu/Ith

 

 

 

IEC 60947-3, EN 60947-3

 

 

 

 

 

 

VDE 0660 Part 107

A

10

10

5

20

20

SEV max.

A

10

10

-

20

20

UL / Canada

A

10

10

5

16

16

Rated Operational Current Ie

 

 

 

 

 

 

 

AC-21A Switching of resistive loads,

including moderate overloads


 

 

 

 

IEC 60947-3, EN 60947-3

A

10

10

upon request

20

20

VDE 0660 Part 107

A

 

 

 

 

 

SEV 400 V

A

10

10

-

-

-

500 V

A

-

-

-

-

-

600 V

A

-

-

-

-

10

AC-15 Switching of control devices, contactors, 

valves etc.  

 

IEC 60947-3 220 V-240 V

A

2,5

2,5

-

6

6

VDE 0660 380 V-440 V

A

1,5

1,5

-

4

4

part 107

           

Pilot Duty

UL/Canada Heavy

VAC

300

300

-

300

600

Ampere Rating

Resistive or low inductive loads.

UL/Canada

A

10

10

-

16

16

Resistive load/Motor load

CEE 24

A

4/2

4/2

-

10/6

10/6

 

NEMKO/FI

A

6/2

-

-

10/6

-


Short Circuit Protection

 

Max. fuse size (gL-characteristics)

A

10

10

5

25

25

Rated short-time withstand current (1 s.current )

A

90

90

30

140

140

Rated Utilization Category

IEC 60947-3, EN 60947-3

           
 

VDE 0660 Part 107

           

Direct on-line starting
Star - Delta starting

 

 

 

 

 

 

3 phase220 V-240 V

 

1,5

1,5

-

3

3

3 pole 380 V-440 V

kW

2,2

2,2

-

5,5

5,5

500 V

-

-

-

-

5,5

5,5

660 V-690 V

-

-

-

-

5,5

5,5

1 phase 110 V-120 V

 

0,3

0,3

-

0,6

0,6

2 pole 220 V-240 V

kW

0,55

0,55

-

2,2

2,2

380 V-440 V

 

0,75

0,75

-

3

3

AC-23A Frequent switching of motors or other high inductive loads

3 phase 220 V-240 V

 

1,8

1,8

-

3,7

3,7

 

3 pole 380 V-440 V

kW

3

3

-

7,5

7,5

 

500 V

 

-

-

-

7,5

7,5

 

660 V-690 V

 

-

-

-

7,5

7,5

 

1 phase 110 V-120 V

 

0,37

0,37

-

0,75

0,75

 

2 pole 220 V-240 V

kW

0,75

0,75

 

2,5

2,5

 

380 V-440 V

 

1,1

1,1

 

3,7

3,7

Ratings

UL/Canada

           

Standard Motor load

110 V-120 V

 

0,75

0,75

-

1,5

1,5

DOL - Rating

3 phase 220 V-240 V

HP

1

1

-

1

3

(Similar AC - 3)

3 pole 440 V-600 V

-

-

-

-

-

5

Max. Permissible Wire Gage

 

 

2x

2x

2x

2x

2x

Single core or stranded wire

 

 

 

mm2

1,5

1,5

1,5

2,5

2,5

AWG

14

14

14

16

16

 

 

 

2x

2x

2x

2x

2x

Flexible wire (sleeving in accordance with DIN 46228)

 

 

 

mm2

1,5

1,5

1,5

1,5

1,5

AWG

16

16

16

14

14